Model TLC System
Model TLC All-Fuel Chimney offers current technology in factory-built chimney design by providing superior performance, durability and safety.
- Embossed Coupler – Prevents moisture penetration
- 304 Stainless Steel Inner Liner – High grade material heats up quickly to enhance draft
- 304 Stainless Steel Outer Casing - Premium material prevents corrosion
- Mineral Wool Insulation - Augured in for better insulating value to keep outside temperatures low for safety and inside temperatures high for performance
- Premium Fiber Insulation – 100% mineral wool (no chlorides)
- Twist-Lock connection – Easy assembly
Enhanced Features
Model TLC is extremely corrosion-resistant. Both the inner liner and outer casings are constructed of 304 stainless steel. Embossed couplers do not allow moisture to penetrate the chimney’s outer wall. Sections simply twist-lock together and are secured with Locking Bands. The Model TLC product line features deluxe chimney support components that will enhance any installation. Black trims are used to embellish the chimney support component parts that may be installed inside the home.
Supports
All Model TLC supports are designed to carry four times the UL-listed weight of the listed height.
Construction
Sizes: 5" to 14"
Inner Liner (Flue):
Type 304 Series Stainless Steel; 0.016" thickness
Outer Casing:
Type 304 Stainless Steel; 0.015" thickness
Insulation:
The 1" space between the inner/outerwalls is packed with mineral wool fiber insulation to provide superior insulating qualities in a slim-line design.
Airspace Clearance to Combustibles: 2"
Certifications & Applications
Model TLC is safety-tested and listed to applicable UL safety standards for chimneys serving solid-fuel and liquid-fuel appliances. This includes UL 103. This chimney system is designed for use on appliances that use solid, liquid or gas fuels under natural draft conditions. Allowable flue gas temperatures are:
Type | HT | Non-HT |
---|---|---|
Size | 5"-8" | 10"-14" |
Maximum Continuous | 1000°F | 1000°F |
Brief Forced Firing (1 hr.) | 1400°F | 1400°F |
Creosote Burn-Out (10 min.) | 2100°F | 1700°F |

- Slim, advanced design allows for installation between 16” centers and still provides 2” clearance from combustible material.
- Secure twist-lock design couples chimney sections together with just a 1/8 turn. Locking bands secure joints.
- Includes locking band.
- Sections overlap by 11/8”.
- Chimneys are sized according to the inner diameter and are available in 5” through 14”.
- The outside diameter is 2” larger than the inside diameter.

- Locking bands are used at all joints for safety and stability.
- Locking band flanges engage the curl in each end of the adjoining sections, holding them securely together.

- The insulated elbow is used when offset is required.
- Locking bands must be used on all elbows.
- A maximum of 6 feet is allowable between offsets.
- Elbow is fully insulated and can be used with the same 2-inch clearance as chimney lengths.
- Elbow support must be used with all offset installations and will support 15 feet of chimney.
- Elbows do not have twist-locking ridges, so they can be rotated to attain optimum positioning offset and allow chimney to return to correct vertical alignment prior to installing locking bands.
- May not be used outdoors.
- Elbow kits include: 2 elbows (Exception: 12” and 14” sizes include four 15° elbows assembled into two 30° elbows) 4 locking bands (Exception: 10”, 12” and 14” sizes include two locking bands) 1 elbow support All hardware

- Permits typical 2” airspace clearance to combustibles.
- 5” to 8” sizes are twist-lock and for non-wall support applications only.
- 10” to 14” sizes are press-fit design.

- The insulated chimney tee may be used for through-the-wall installation, using awall support.
- A chimney length is required to pass safely through a wall.
- Includes the following:
- Two locking bands
- 5” to 8” sizes have an uninsulated (single-wall) twist-lock tee cap for non-wall support applications only.
- 10” to 14” sizes have an insulated press fit tee cap.

- Used where the chimney passes through a roof with apitch of 6/12 to 12/12.
- Comes complete with storm collar.
- All seams are sealed with silicone sealant.
- Galvalume construction.

- Used where the chimney passes through a roof with apitch of Flat to 6/12.
- Comes complete with storm collar.
- All seams are sealed with silicone sealant.
- Galvalume construction.

- 0/12 to 2/12 pitch.
- All seams are sealed with silicone sealant.
- Galvalume construction.
- Comes complete with storm collar.

- This kit fits 5”, 6”, 7” and 8” chimneys.
- Used where the chimney passes through a corrugated roof.
- 8" Rubber boot flashing fits roof pitches up to 10/12
- 5"-7" Rubber boot flashing fits roof pitches up to 12/12.
- UL-listed
- Kit includes:
- Special Storm Collar
- Rubber Boot
- Spacer Kit
- Special Boot-Mounting Screws

- Used in conjunction with roof flashing to keep precipitation out.

- Used to seal storm collar to chimney length above cone of flashing.
- 3-ounce tube.

- Matte black finish.
- Adjusts to multiple roof pitches.
- Covers 2-inch space around chimney for attractive finish

- Used when more than 5 feet of chimney extends from the roof.
- The kit includes two rods and an adjustable band.
- Each rod extends to 4 to 6feet.
- The adjustable band will fit 5” to 14” sizechimney.
- Sizes available: 7 to 16

- Insulation for use with Attic Insulation Shield, Wall Thimble and Cathedral Ceiling Support Box.
- Protects building materials against radiant heat from the chimney.
- Helps maintain temperatures within the chimney system and within the housing envelope to prevent condensation on exterior.
- UL-listed.

- Used where the chimney passes through a soffit to provide a finished appearance.
- Maintains the mandatory 2-inch clearance to combustibles.

- For quick and easy transition from blackstovepipe to factory-built chimney.
- Twist-lock for easy connection.
- 5” to 8” is black.

- Used on wall support installations when passing through a noncombustible wall.
- Matte black finish with brass trim for an enhanced hand-crafted appearance.

- Stainless steel construction.
- Provides lateral support for the chimney when installed adjacent to a wall.
- Maintains the mandatory 2-inch clearance to combustibles.
- Used 4 feet above the tee, then every 8feet thereafter.

-
Now UL Approved on Class A Chimneys UL 103HT for use with AmeriVent TLC® chimneys.
-
Available in 5" to 8" Diameters
-
Heavy Duty Construction: Built with high-quality 300 Series stainless steel for long-life and durability.
-
Easy to Install & Remove for Inspection & Cleaning:Great after-market cap solution for chimneys with downdraft or replacement issues.
-
Smart Choice Lifetime Limited Warranty: Covers defects in material and workmanship.

- Advanced design, premium quality stainless steel.
- Provides protection against the elements.
- Twist-lock connection for secure installation.

- For use with 6” to 14” caps.

- Required where an enclosed chimney passes from a lower living space into an upper living space.
- Maintains the mandatory 2-inch clearance to combustibles.
- Joist Shield is used in floor/ceiling penetrations, other than those that include a ceiling support.
- Joist Shield not required when passing through roof.

- The attic insulation shield must be installed where the chimney enters the attic space in any installation.
- Designed to keep insulation away from the chimney and to maintain the mandatory 2-inch clearance to combustibles.
- Must be used when the chimney penetrates an unoccupied attic.
- Not to be used for enclosed chimneys.

- The rafter radiation shield must be installed immediately below the roof if the chimney is enclosed.

- Used in a wall support installation.
- Radiation shield is included with spacers, which maintain the mandatory 2-inch clearance to combustibles.
- Attractive matte black finishing trim is included with stylish brass finish.
- Adjustable wall thickness from 4½” to 8¾” for 5” to 8” sizes and from 6” to 11” for 10” to 14” sizes.
- 10” to 14” sizes have a round face plate without brass trim.

- To be used with specifically listed zero-clearance fireplaces for direct connection of all-fuel chimney.
- 5” to 8” sizes are 14-gauge galvanized base plate, and 10” to 14” sizes are 10-gauge galvanized base plate.

- Used to support the chimney on a through-the-wall installation.
- 5” to 8” sizes include top plate, side brackets, hardware, non-twist-lock insulated tee cap, and a long L-bracket to hold tee cap in place.
- 10” to 14” sizes do not include the cap. Use tee cap packaged with tee.
- 2” to 6” clearance away from wall.
- 5” to 8” sizes support between 30feet and 74 feet ofchimney, based on size and orientation. Seeinstructions for specific heights.
- 10” to 14” sizes support up to 40feet of chimney.
- 12”to 14” sizes are nonadjustable supports.
Non-Twist-Lock Insulated Tee Cap (5” to 8” sizes) L-Bracket (5” to 8” sizes)

- For use in ceiling support installations.
- Supports a total of 50feet of chimney above.
- Chimney pipe cannot pass below support.
- Matte black finish with brass finishing ring, support gives a premium finished appearance.
- Also acts as a firestop.
- Must always use stovepipe adapter.

- Used in pitched ceiling support installations.
- Supports a total of 38 feet of chimney with up to 15 feet below support. Includes support clamp, allowing chimney pipe to pass belowsupport.
- Matte black finish with stylish brass finishing trim and ceiling trim to cover rough opening.
- Also acts as a firestop with use of trim plate.
- 12/12 maximum pitch.

- 5" to 8" sizes
- Used with the Wall Support (TLCAWS) and L-Bracket

- Used as supplementary support when chimney system height exceeds maximum height allowed by wall support.
- Supports an additional 38 feet of chimney.
- Includes top plate, support band, side brackets, and hardware.
- 2” to 6” clearance away from wall.

- The roof support may be used on a roof and adjusts to any roof pitch.
- It may be used above an offset to support the offset or as a supplementary support when the chimney height exceeds that of the primary support.
- Supports a total of 30 feet of chimney with up to 20 feet below support.
- Does not act as a firestop.
- Larger models contains one 18-inch length of pipe with roof brackets preinstalled. Includes hardware.